Drop Out Fuse for Transformer Protection
Ampere: 100A, 200A.
Polymer cutout fuse, Polymer dropout fuse.
Porcelain cutout fuse, Porcelain dropout fuse.

Product Description
* Series Cutout Fuse
* Best quality, competitive price1
10KV, 11KV, 12KV, 15KV, 24KV, 27KV, 33KV, 36KV, 38KV
Ampere: 100A, 200A.
Polymer cutout fuse, Polymer dropout fuse.
Porcelain cutout fuse, Porcelain dropout fuse.
High Voltage Cut Out Fuse / Dropout Fuse
Dropout fuse cutouts and load switching fuse cutouts are for outdoor used high voltage protective device. To be connected with in coming feeder of distributing transformer or distribution lines. It mainly protect transformer or lines from short circuit and overload, and on/off loading current. Dropout fuse cutout is composed of insulator supports and fuse tube, static contacts are fixed on two sides of insulator support and moving contact is installed on two ends of fuse tube. Fuse tube is composed of inside arc-exiting tube, outer phenolic compound paper tube or epoxy glass tube. Load switch fuse cutout provides enforced elastic auxiliary contacts and arc-extinguishing enclosure for switching on/off loading current.
In the normal working, the fuse tube is formed up of close position via the fuse link tightened. In case the system occur faults, fault current results in fuse melt immediately and forms electric arc, which let arc-extinguishing tube be heated and explode a lot of gas. Those will produce high pressure and blow off the arc along with tube immediately. After fuse link melt, the moving contact drops out without tightened strength, mechanism is locked and fuse tube drop out, then form a distinct open position. When it needs to disconnect in loading, the operator shall pull the moving contact via insulating operating bar. At the moment, the main contact and auxiliary static contact are still contacted. Be continued to pull the contact, then the auxiliary contact is separated, it produced the electric arc between the auxiliary contacts. The arc is lengthened in arc-extinguishing enclosure gap, meanwhile, the arc shield explode gas to blow off the arc during the current passes zero.
Rated voltage: 10KV, 11KV, 15KV, 24KV, 27KV, 30KV, 33KV, 36KV, 38KV etc.
Material: Porcelain type, Polymeric type.
12kv-15kv High Voltage Dropout Fuse
Type | Rated volage | Rated | Breaking | Impulse | Power-frequency | Leakage distance | Weight | Dimensions |
CEC-102 | 15 | 100 | 10000 | 125 | 45 | 330 | 8 | 51×32.5×12 |
CEC-202 | 15 | 200 | 12000 | 125 | 45 | 330 | 8.5 |
We mainly produce HV Dropout Fuse, Lightning Arrestor, Isolate Switch, Poleline Hardware, solar photovoltaic fittings, etc. Welcome to contact us for business.
Hot Tags: drop out fuse for transformer protection, China, drop out fuse for transformer protection manufacturers, suppliers, factory, fuse for washing machines, fuse for fax machines, fuse for coffee makers, fuse for transformers, safety fuse, porcelain post insulators
Previous
Expulsion Drop Out Cutout FuseNext
Fuse Switch 630AYou Might Also Like
Send Inquiry